MOUNTING AND WIRING THE SAFETY

Figure 5

REVERSING SENSORS

Wing Nut

• Slide a 1/4"-20x1/2" carriage bolt head into the slot

1/4"-20

 

on each sensor. Use wing nuts to fasten sensors to

 

 

brackets, with lenses pointing toward each other

 

 

across the door. Be sure the lens is not obstructed

Carriage Bolt

 

by a bracket extension (Figure 5).

 

1/4"-20x1/2"

Finger tighten the wing nuts.

Lens

 

Run the wires from both sensors to the opener. Use

TROUBLESHOOTING THE SAFETY

 

insulated staples to secure wire to wall and ceiling.

 

REVERSING SENSORS

Strip 1/4" (6 mm) of insulation from each set of

1. If the sending eye indicator light does not glow

 

wires. Separate white and white/black wires

 

steadily after installation, check for:

 

sufficiently to connect to the opener terminal

 

• Electric power to the opener.

 

screws: white to 2 and white/black to 3 (Figure 6).

 

• A short in the white or white/black wires. These

ALIGNING THE SAFETY REVERSING SENSORS

can occur at staples, or at terminal connections.

 

Plug in the opener. The indicator lights in both the

• Incorrect wiring between sensors and opener.

 

sending and receiving eyes will glow steadily if

 

• A broken wire.

 

wiring connections and alignment are correct.

 

2. If the sending eye indicator light glows steadily but

The sending eye amber indicator light will glow

the receiving eye indicator light doesn't:

regardless of alignment or obstruction. If the green

• Check alignment.

indicator light in the receiving eye is off, dim, or

flickering (and the invisible light beam path is not

• Check for an open wire to the receiving eye.

obstructed), alignment is required.

3. If the receiving eye indicator light is dim, realign

Loosen the sending eye wing nut and readjust,

either sensor.

 

aiming directly at the receiving eye. Lock in place.

NOTE: When the invisible beam path is obstructed

Loosen the receiving eye wing nut and adjust

or misaligned while the door is closing, the door will

 

sensor until it receives the sender’s beam. When

reverse. If the door is already open, it will not close.

 

the green indicator light glows steadily, tighten the

The opener lights will blink 10 times. (If bulbs are not

 

wing nut.

installed, 10 clicks can be heard.) See page 21.

 

 

Connect Wire to

Figure 6

Opener Terminal Screws

 

Finished Ceiling

 

 

Bell Wire

 

Safety Reversing Sensor

Bell Wire

 

Sensor

Door Control

 

Connections

Connections

 

 

 

(dotted line)

 

 

1

2

3

OPENER TERMINAL SCREWS

Safety Reversing Sensor

Invisible Light Beam

Protection Area

23