MOUNTING AND WIRING THE SAFETY | Figure 5 | ||
REVERSING SENSORS | Wing Nut | ||
• Slide a | |||
| on each sensor. Use wing nuts to fasten sensors to |
| |
| brackets, with lenses pointing toward each other |
| |
| across the door. Be sure the lens is not obstructed | Carriage Bolt | |
| by a bracket extension (Figure 5). | ||
| |||
• | Finger tighten the wing nuts. | Lens | |
| |||
• | Run the wires from both sensors to the opener. Use | TROUBLESHOOTING THE SAFETY | |
| insulated staples to secure wire to wall and ceiling. | ||
| REVERSING SENSORS | ||
• | Strip 1/4" (6 mm) of insulation from each set of | ||
1. If the sending eye indicator light does not glow | |||
| wires. Separate white and white/black wires | ||
| steadily after installation, check for: | ||
| sufficiently to connect to the opener terminal | ||
| • Electric power to the opener. | ||
| screws: white to 2 and white/black to 3 (Figure 6). | ||
| • A short in the white or white/black wires. These | ||
ALIGNING THE SAFETY REVERSING SENSORS | |||
can occur at staples, or at terminal connections. | |||
• |
| ||
Plug in the opener. The indicator lights in both the | • Incorrect wiring between sensors and opener. | ||
| sending and receiving eyes will glow steadily if | ||
| • A broken wire. | ||
| wiring connections and alignment are correct. | ||
| 2. If the sending eye indicator light glows steadily but | ||
The sending eye amber indicator light will glow | |||
the receiving eye indicator light doesn't: | |||
regardless of alignment or obstruction. If the green | |||
• Check alignment. | |||
indicator light in the receiving eye is off, dim, or | |||
flickering (and the invisible light beam path is not | • Check for an open wire to the receiving eye. | ||
obstructed), alignment is required. | 3. If the receiving eye indicator light is dim, realign | ||
• | Loosen the sending eye wing nut and readjust, | ||
either sensor. | |||
| aiming directly at the receiving eye. Lock in place. | NOTE: When the invisible beam path is obstructed | |
• | Loosen the receiving eye wing nut and adjust | ||
or misaligned while the door is closing, the door will | |||
| sensor until it receives the sender’s beam. When | reverse. If the door is already open, it will not close. | |
| the green indicator light glows steadily, tighten the | The opener lights will blink 10 times. (If bulbs are not | |
| wing nut. | installed, 10 clicks can be heard.) See page 21. | |
|
| Connect Wire to | |
Figure 6 | Opener Terminal Screws | ||
| Finished Ceiling |
| |
| Bell Wire |
|
Safety Reversing Sensor
Bell Wire |
| Sensor |
Door Control |
| Connections |
Connections |
| |
|
| |
(dotted line) |
|
|
1 | 2 | 3 |
OPENER TERMINAL SCREWS
Safety Reversing Sensor
Invisible Light Beam
Protection Area
23