The receiver can be used with a multi-function remote control to operate three residential garage door openers, or with a three-button door control to OPEN, CLOSE or STOP a commercial garage door opener. Not for use on residential fail-safe operators.

INSTALLATION

The receiver and antenna use TV Type F coaxial connectors. The antenna can be plugged directly into the receiver or mounted to a bracket and connected to the receiver with Model 86 Coaxial Cable Kit, depending on your requirements.

Select a location for the receiver which allows access to the terminals and space for the antenna (as far from metal structures as possible and preferably with the antenna in an upright position). Fasten the receiver securely with screws through the two holes provided in the cover flanges.

To use the receiver with a 3-button door control and a commercial door opener:

Consult your manufacturer’s control connection diagram for instructions on connecting two or more 3-button control devices. Figure 1.

• Use a screwdriver to pry open the receiver cover.

NOTE: The slide switch is factory set to the N.C. position (other- wise the opener will not operate). Verify this setting. Re-connect power to the opener and the accessory transformer, if used.

3-Channel Receiver

Model 323LM
OWNERS MANUAL

WARNING

To prevent possible SERIOUS INJURY or DEATH from electrocution:

• Be sure power is not connected BEFORE installing the receiver.

To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door:

ALWAYS keep remote controls out of reach of children. NEVER permit children to operate, or play with remote control transmitters.

Activate gate or door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.

ALWAYS keep gate or garage door in sight until completely closed. NEVER permit anyone to cross path of moving gate or door.

WARNING

To prevent possible SERIOUS INJURY or DEATH, the use of CONSTANT OPERATION on residential openers is PROHIBITED.

WARNING

When a receiver is used to activate a commercial door opener, a reversing edge MUST be installed on the bottom of the door. Failure to install a reversing edge under these circumstances may result in SERIOUS INJURY or DEATH to persons trapped beneath the door.

Figure 1

Example of Operator

 

 

 

 

Terminal Strip

 

 

 

COAXIAL

 

 

 

 

RECEIVER

 

 

Figure 2

 

 

 

 

Connect

 

24Vac

CONTROL

 

Antenna

1

OPENING RECEIVER

 

 

STATION

 

C(Blue)

 

 

2

 

 

 

 

B(Yellow)

STOP

OPEN

 

 

3

 

 

 

 

 

 

 

A(Grey)

Wire nut

 

 

C

4

 

CLOSE

 

B

 

 

 

 

 

COMMON

 

 

A

 

 

STOP

 

 

Close

Open

Stop

CLOSE

OPEN

Slide Switch – N.C. Position

Select a remote control push button to STOP the opener. (It is recommended that you use the large button on remote).

Press and hold the selected remote push button.

Then press and release the “learn” button labeled “A” on the receiver. The adjacent indicator light will FLASH.

Release the remote push button.

Repeat the procedure above with a second remote push button and receiver “learn” button “B” to program the OPEN operation; and again with the last remote push button and receiver “learn” button “C” to program the CLOSE function of the opener.

Return the front cover to the receiver.

NOTE: If a remote control push button is not pressed within 30 seconds, the indicator light adjacent to the selected “learn” button will turn OFF. In that case, repeat the programming.