INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of door and door hardware. The installation surface must be smooth and flat. If installing into drywall, drill 5/32" holes and use anchors provided. For pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 1). NOTE: After installation, a green or amber indicator light behind the cover will indicate proper connection. If not lit, the Lock and Light features will not function (reverse wires to correct).

1. Strip 7/16" (11 mm) of insulation from one end of bell

wire and connect to the two screw terminals on back of

door control by color: white wire to WHT and white/red

wire to the RED (Figure 2).

2. Remove white cover by gently prying on a side corner

near the top of the cover with a small flat head

screwdriver (Figure 3). Fasten with 6ABx1-1/4"

self-tapping screws (drywall installation) or 6-32x1"

machine screws (into gang box) as follows:

• Drill and install bottom screw, allowing 1/8"(3 mm) to

protrude above wall surface.

• Position bottom of door control on screw head and

slide down to secure. Adjust screw for snug fit.

• Install top screw with care to avoid cracking plastic

housing. Do not overtighten.

• Insert bottom tabs and snap on cover (Figure 4).

To prevent possible SERIOUS INJURY or DEATH from electrocution:

Be sure power is NOT connected BEFORE installing door control.

Connect ONLY to 24 VOLT low voltage wires.

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m) and away from ALL moving parts of door.

NEVER permit children to operate or play with door control push buttons or remote control transmitters.

Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.

ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

HARDWARE SHOWN ACTUAL SIZE

Screw 6ABx1-1/4"

Insulated

 

Staples

Screw 6-32x1"

 

(pre-wired installation)

Drywall Anchors

NOTE: The push bar may stick if the door control is not mounted on a smooth surface. If a click is not heard when pressing the push bar, loosen the two mounting screws or relocate the door control to a smoother surface.

3. (Standard installation only) Run bell wire up wall and

across ceiling to motor unit. Use insulated staples to

secure wire in several places. Do not pierce wire with

a staple, creating a short or open circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals as

follows: white to white and white/red to red (Figure 5).

Figure 1

PRE-WIRED

Figure 2 INSTALLATION

LOCK

 

LIGHT

 

To Replace

24 Volt

Insert Bottom Tabs First

2-Conductor

 

Bell Wire in

 

Gang Box

Figure 2

Top Mounting Hole

Terminal

Screws

RED WHT

Bell Wire

Bottom Mounting Hole

NOTE: When connecting multiple door controls to the

opener, twist same color wires together. Insert wires

into quick-connect holes: white to white and red/white

to red.

5. Use tacks or staples to permanently attach entrapment

warning label to wall near door control, and manual

release/safety reverse test label in a prominent

location on inside of garage door.

NOTE: DO NOT connect power and operate opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.

Figure 3

Figure 4

 

LOCK

 

LIGHT

 

To Replace

 

Insert Bottom Tabs First

Figure 5

 

Door Control

To insert or release wire, push

Connections

in tab with screwdriver tip

Red White Grey

7/16" (11 mm)

Strip wire 7/16" (11 mm)

17