Automatic Computerized Drying Control
DETAILSOF CONTROL BOARD AND OPTIONS
OPTIONS SWITCH SET #1
Switch |
| ON | OFF | |
#8 F/C |
| Deg F | Deg C | |
#7 |
| Enabled | Disabled | |
#6 |
| + 6 Min. | 0 | |
#5 | Repeat S/E |
| Start | End |
#4 | 2 Deg. |
| + 2 Deg. | 0 |
#3 | 5 Deg. |
| + 5 Deg. | 0 |
#2 | 10 Deg. |
| + 10 Deg. | 0 |
#1 | 20 Deg. |
| + 20 Deg. | 0 |
#8 | F/C | Selection of Deg F or Deg C for |
| |
|
| temperature display. |
| |
#7 |
| The switch enables the “safety |
| |
|
|
| tumble” feature. To disable, position | |
|
|
| this switch in the OFF position. |
|
#6 | Used in conjunction with the HEAVY |
| ||
|
| Fabric Selection to add 6 minutes to |
| |
|
| drying time (auto mode) for hard to dry” | ||
|
| loads. |
| |
#5 | Repeat S/E | This switch works in conjunction | ||
|
|
| with the REPEAT LAST CYCLE | |
|
|
| button. The cycle settings will be | |
|
|
| stored either at the START or the | |
|
|
| END of the cycle, based on this | |
|
|
| switch setting. The stored settings | |
|
|
| will be used when REPEAT LAST | |
|
|
| CYCLE is pressed. |
|
#4 | 2 DEG. |
| Adds 2 degrees to the differential |
|
|
|
| temperature. |
|
#3 | 5 DEG. |
| Adds 5 Degrees to the differential |
|
|
|
| temperature. |
|
#2 | 10 DEG. |
| Adds 10 Degrees to the differential | |
|
|
| temperature. |
|
#1 | 10 DEG. |
| Adds 10 Degrees to the differential | |
|
|
| temperature. |
|
NOTE
The differential temperature is part of the heating logic. The heat turns off when the temperature in the dryer reaches the temperature set for the drying cycle. The temperature has to drop a set number of degrees below the drying temperature before the heat will turn on. The difference between the cycle temperature and the temperature to turn the heat on is called the differential temperature. This control allows the differential to be set between 5 and 25 degrees. The control “sums” the values set on the switches but will not go lower than 5 nor greater than 25. If the sum is less than 5 the control will default to 5. If the sum is greater than 25, the control will default to 25.
Page 35