Inputs
Select which input (1–12) you want to monitor on the LCD and LED display. Scroll
to the input, then press Enter. The meter displayed is the post-gain meter.
Outputs
This submenu allows you to choose which output (1–12) you want to monitor on the
LCD and LED display. Scroll to the output you want to monitor, then press Enter.
Processing
This submenu allows you to choose which processing channel (A–H) you want to
monitor on the LCD and LED display. Scroll to the output you want to monitor, then
press Enter.
ERL
This submenu allows monitoring of the ERL meters on the XAP 800. Select the
meter you want to monitor and press Enter.
ERLE
This submenu allows monitoring of the ERLE meters on the XAP 800. Select the
meter you want to monitor and press Enter.
Default Meter
This submenu determines what is displayed on the LED meter when a meter is not
specifically selected elsewhere in the Meter menu. The default is Output 12.
The Meter Reference Point diagram on page 19 shows the meter pick-up
points ( ) in the XAP 800 signal path.
Inputs menu
There are two submenus under the Inputs menu: Mute and Gain. To access these
submenus you must first select the input. Choose from Inputs 1–12 or Global. Use
the and buttons to select the Inputs menu, then scroll through the options and
press Enter when you reach the desired option.
Mute
This submenu allows you to turn mute on or off (default) for the selected input.
M