8. Highlight Option B, Management Agent Configuration, using the down
arrow key or <Tab> key. Then press <Enter>. The Management Agent
Configuration screen appears.
Figure 4-6. Management Agent Configuration Screen
9. Use the arrow or tab keys to move to the IP Address field. Then enter the
IP address for the Ethernet interface. To set the IP address for other
interfaces (for example, SLIP), use the “<” and “>” keys to scroll to
group and repeat this step.
10. Move the cursor to the Accept Changes field and press <Enter>. Then
move the cursor to the Return to menu field and press <Enter>.
11. Select Option J (Logout) to log out of the VT100 session.
You can change the initialization string using the Modem Setup screen of the
VT100 interface. For example, you could set the string as “Enter VT100 now”
to provide a more instructive cue to enter the VT100 command. You can also
change the password to log in to VT100 using the Change Password screen. For
a complete description of the VT100 interface, see Appendix B “Using the
VT100 Interface.”