APPENDIX B

CLEARANCE TO COMBUSTIBLES

The following clearances meet the minimum requirements for a safe installation

Sidewall:

18 inches measured from the outer door edge hinge

Ceiling:

7 feet from the base of the fireplace

Fireplace Enclosure:

Bottom:

0

 

Side:

1 inch

 

Back:

½ inch

 

Top:

2 ½ inches. Header may rest on top of top spacer.

NOTE: Combustible material cannot be used in the space directly above the fireplace.

Mantel:

Ducts closed with top grill open

71 inches

Mantel:

With 31/2 inches brick on front

59 inches

Mantel:

Ducts open & top grill open

55 inches

Mantel:

Ducts open & top grill closed

45 inches

Hearth:

Fireplace Width (42 + 8 + 8)

58 inches

Hearth:

Depth from front of fireplace

24 inches

NOTE: Mantel measurements are from the bottom of the Inglenook Fireplace unit.