Crestron CHV-TSTATRF infiNET™ Thermostat

CHV-TSTATRF in Heat-Cool Application with Integrated Control Unit

(Refer to “Basic Thermostat
Setup” on page 15)
Transformer
C
W
Y
G
R
Optional, for power
RH and RC jumpered
since control unit has
them on a single terminal
Heat
Relay
Fan
Relay
Cool
Relay
R
C

CHV-TSTATRF in Heat Pump System Application with Integrated Controller

RH and RC jumpered
since control unit has
them on a single terminal
Optional, for power
Transformer
R
C
C
Y
G
O
E - U - W
R
Compressor
Relay
Fan
Relay
Changeover
Valve
Aux Heat
Relay
(Refer to “Basic Thermostat
Setup” on page 15)
NOTE: Heat pump and dual-fuel heat pump systems require an outdoor temperature sensor (e.g. Crestron’s C2N-RTHS, sold separately) to function properly. In SIMPL Windows, connect the “Temp” output of the sensor to the “OutdoorTemp” input of the CHV-TSTATRF. For details, refer to the SIMPL Windows help file. If using D3 Pro or SystemBuilder refer to “Programming with Crestron D3 Pro or SystemBuilder” on page 27

Operations & Installation Guide – DOC. 6490 infiNET™ Thermostat: CHV-TSTATRF 13