TROUBLE SHOOTING GUIDE

CONDITION

CHECK

RESULT

CAUSE

REMEDY

Outlet has

Check continuity of magnetron

No

Defective

Replace

 

proper

Continuity

magnetron

 

 

 

voltage Fuse

 

 

 

 

does not

 

 

 

Replace

blow.

Check continuity of

No

Defective line

 

 

 

noise filter board

Continuity

filter board

 

 

Check continuity of

No

Open power

Replace

 

 

 

power supply cord

Continuity

supply cord

 

 

 

Normal

Defective touch

Replace

 

 

 

 

 

 

 

control circuit

 

NOTE

All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.

(TROUBLE 2) Display shows all figures selected, but oven does not start cooking, even though desired program and time are set and start pad is tapped.

CONDITION

Turn table motor and oven lamp do not turn on

CHECK

Check continuity of primary

interlock switch

Check continuity of secondary interlock and D.O.M. switches

Check D.C. voltage being

supplied to RELAY (RY2) coil

RESULT

No

Continuity

No

Continuity

0 V

Approx. 15 VDC

CAUSE

Malfunction of

primary interlock

switch

Malfunction of

primary interlock

and D.O.M.

switch

Defective touch

control circuit

Faulty contacts of RELAY (RY2) or open relay coil

REMEDY

Adjust or

replace

Adjust or

replace

Replace

Replace

46

Page 47
Image 47
Daewoo KOG-374R0S, KOG-371H0S, KOG-373R0S, KOG-375R0S, KOG-393R0S, KOG-391H0S, KOG-391G0S, KOG-376T1S service manual Check