READING FEATURES
7
Special models with different FOV and focus distance are available on request. Refer to your
local Datalogic distributor.
All distances indicated from the reading window to the code surface are the same for 90°
models.
READING FEATURES
Frame Rate Up to 60 frames/sec. with VGA images
Readable Codes
per Frame Up to 100
Pitch 10° - 35°
Tilt 0° - 360°
Reading
Distance (3)
mm (in)
MODELS
Focus
Distance
mm (in) Field of View (1)
mm (in) ppi(2)
Typ. Linear and
Stacked
Code Resolution
mm (mils)
Typ. 2D Code
Resolution
mm (mils)
min. max.
2X11 UHD 60
(2.36)
17 × 13
(0.67 × 0.51) 955 0.10
(4)
0.13
(5)
51
(2.00)
74
(2.91)
2X21 HD 85
(3.35)
25 × 19
(0.98 × 0.75) 653 0.10
(4)
0.19
(7.5)
78
(3.07)
93
(3.66)
2X31 SD 115
(4.53)
34 × 26
(1.34 × 1.02) 478 0.15
(6)
0.25
(10)
100
(3.94)
130
(4.53)
2X41 LD 80
(3.15)
54 x 40
(2.13 × 1.57) 300 0.20
(8)
0.38
(15)
70
(2.76)
105
(4.13)
2X51 MR 160
(6.29)
95 × 70
(3.74 × 2.75) 170 0.30
(12)
0.60
(24)
120
(4.72)
220
(8.66)
2X61 LR 500
(19.69)
110 × 82
4.33 × 3.23) 148 0.30
(12)
0.60
(24)
430
(16.93)
570
(22.44)
(1) @ Focus Distance
(2) Pixels per inch @ Focus Distance
(3) Measurement Conditions:
Test Chart: provided with the reader
Still code at the center of the FOV
Code Symbology: Data Matrix ECC 200
Code Resolution: Max. 2D Code Resolution
Tilt Angle: 45°
Skew Angle: 15°
Image Processing Mode: Advanced Code Setting
Depending on the code resolution, symbology and number of characters in the code, the Reading Area can be different from the
FOV.
65