Delta Electronics VFD-VL manual Year, Visual, aural inspection and smell Or peculiar smell

Models: VFD-VL

1 251
Download 251 pages 18.69 Kb
Page 190
Image 190

 

 

Chapter 6 Fault Code Information and Maintenance

 

„ DC capacity of main circuit

 

 

 

 

 

 

 

Maintenance

 

Check Items

Methods and Criterion

 

Period

 

 

Daily

Half

One

 

 

 

 

 

 

Year

Year

 

 

 

 

 

 

 

If there is any leak of liquid,

 

 

 

 

 

color change, crack or

Visual inspection

{

 

 

 

deformation

 

 

 

 

 

If the safety valve is not

Visual inspection

{

 

 

 

removed? If valve is inflated?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure static capacity when

 

{

 

 

 

required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

„ Resistor of main circuit

 

 

 

 

 

 

 

Maintenance

 

Check Items

Methods and Criterion

 

Period

 

 

Daily

Half

One

 

 

 

 

 

 

Year

Year

 

 

 

 

 

 

 

If there is any peculiar smell or

Visual inspection, smell

{

 

 

 

insulator cracks due to overheat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If there is any disconnection

Visual inspection

{

 

 

 

 

 

 

 

 

 

If connection is damaged?

Measure with multimeter with standard

{

 

 

 

 

specification

 

 

 

 

 

 

 

 

 

„Transformer and reactor of main circuit

 

 

Maintenance

Check Items

Methods and Criterion

 

Period

 

Daily

Half

One

 

 

 

 

Year

Year

 

 

 

 

 

If there is any abnormal vibration

Visual, aural inspection and smell

{

 

 

or peculiar smell

 

 

 

 

 

 

 

 

 

 

 

Revision Nov. 2008, VLE1, SW V1.03

6-13

Page 190