124
RTC error
Problem
The system has failed to set the date & time to the
real time clock RTC (the so-called "calendar clock")
or has failed to read out from it.
If this error occurs, the BHT-6000 beeps five
times (for 0.1 second per beep) and then turns
itself off.
Solution
Turn on the power again. If this error occurs fre-
quently, contact your nearest dealer.
NOTE
Memory backup test 1
Problem
An error is found in the system area of the RAM or
flash ROM during the memory backup test acti-
vated when the power is turned on.
(This error message will appear also when the
power is first applied from the time of purchase.)
This error message will appear either in Eng-
lish or Japanese.
Solution
Initialize the BHT-6000. (For the initialization pro-
cedure, refer to Chapter 2, Subsection 2.4.2, [ 1 ].)
If the error persists even after initialization, con-
tact your nearest dealer.
NOTE
Memory backup test 2
Problem
An error is found in the user area of the RAM or
flash ROM during the memory backup test acti-
vated when an application program is initiated.
Solution
Operate the BHT-6000 in System Mode and test
files by executing "8: FILE" in the TEST menu.
Download or delete defective files marked with an
asterisk (*), then run the application program again.
(For details, refer to Subsection 2.5.3, [5.8].)
RTC error!
Contact your
administrator.
System error!
Contact your
administrator.
Note the
error drive.
(DRIVE X)
Application
error!
Contact your
administrator.