52
[4.6-2] Setting the communications parameters for the direct-connect
interface
SET CONNECTOR
1:TRANSMIT SPEED
2:PARITY BIT
3:DATA BIT
4:STOP BIT
5:PROTOCOL
Selecting "2:CONNECTOR" on the SET COM menu
calls up the screen shown at left.
1 TRANSMIT SPEED: Switches to the transmis-
sion speed screen.
2 PARITY BIT: Switches to the parity set-
ting screen.
3 DATA BIT: Switches to the character
length screen.
4 STOP BIT: Switches to the stop bit
length screen.
5 PROTOCOL: Switches to the commu-
nications protocol option
menu.
Select a desired screen by using the numerical
keys or F5 and F6 keys, and then press the
ENT key.
To return to the SET COM menu, press the C key.
If the BHT-Ir protocol has been selected, the
parity bit, character length, and stop bit length
settings will be ignored.
(1) Transmission speed screen
SET SPEED
< CONNECTOR >
1:1200 4: 9600
2:2400 5:19200
3:4800 6:38400
Selecting "1:TRANSMIT SPEED" on the SET CON-
NECTOR screen calls up the screen shown at left.
Select the desired transmission speed by using
the numerical keys or F5 and F6 keys, and then
press the ENT key.
To return to the SET CONNECTOR screen, press
the C key.
(2) Parity setting screen
Selecting "2:PARITY BIT" on the SET CONNECTOR
screen calls up the screen shown at left.
Select the parity: none, odd or even, by using the
numerical keys or F5 and F6 keys, and then
press the ENT key.
To return to the SET CONNECTOR screen, press
the C key.
SET PARITY BIT
< CONNECTOR >
1:None
2:Odd
3:Even
NOTE