Desa GVR50PA, GVR65PA, GVR65BPA, GVR35PA, GVR50BPA installation manual Ing statement at, Top

Models: GVR65BPA GVR35PA GVR50PA GVR50BPA GVR65PA

1 44
Download 44 pages 11.47 Kb
Page 31
Image 31

TROUBLE-

WARNING ICONG 001WARNING

SHOOTING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

REMEDY

 

 

 

PROBLEM

CAUSE

 

 

 

 

 

 

 

 

Heater produces

1. Heater burning vapors

1.

Ventilate room. Stop

unwanted odors.

 

from paint, hair spray,

 

using odor causing

 

 

glues, etc.

 

products while heater is

 

 

 

 

running.

 

2.

Low fuel supply

2.

Refill supply tank.

 

3.

Gas leak. See Warn-

3.

Find and correct all

 

 

ing statement at

 

leaks (see Checking Gas

 

 

top of page.

 

Connections, page 13).

 

 

 

 

 

 

 

Heater shuts off in

1.

Heater not venting

1.

Check

venting system.

use.

 

correctly. Vent safety

 

If damaged or blocked,

 

 

switch shuts off

 

repair. If venting system

 

 

heater.

 

is OK,

have qualified

 

 

 

 

service

person replace

 

 

 

 

vent safety switch, wire

 

 

 

 

harness, or thermo-

 

 

 

 

couple interrupter.

 

2.

Low line pressure.

2.

Contact local propane

 

 

 

 

gas company.

 

3.

Pilot partially clogged.

3.

Clean pilot (see Clean-

 

 

 

 

ing and Maintenance,

 

 

 

 

page 26).

 

 

 

 

 

Gas odor even when

1. Gas leak. See Warn-

1.

Find and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position.

 

top of page.

 

Connections, page 13).

 

2.

Control valve damaged.

2.

Replace control valve.

 

 

 

 

 

Gas odor during

1. Foreign matter be-

1.

Take apart gas tubing

combustion.

 

tween control valve

 

and remove foreign

 

 

and burner.

 

matter.

 

 

 

 

2.

Gas leak. See Warn-

2.

Find and correct all

 

 

ing statement at

 

leaks (see Checking Gas

 

 

top of page.

 

Connections, page 13).

 

3.

Foreign fumes in area

3.

Ventilate area around

 

 

of heater being drawn

 

heater to remove any

 

 

through burner com-

 

foreign fumes.

 

 

 

 

 

31

 

 

 

 

 

bustion.

 

 

 

 

 

 

 

 

 

 

 

100791

Page 31
Image 31
Desa GVR50PA, GVR65PA, GVR65BPA, GVR35PA, GVR50BPA installation manual Ing statement at, Top