Troubleshooting

WARNING: Never attempt to service heater while it is connected to propane/LP supply, operating, or hot. Severe burns can occur.

SYMPTOM

POSSIBLE CAUSE

REMEDY

 

 

 

 

Burner fails to light

1. Propane/LP supply valve

1.

Open propane/LP supply

 

 

closed on propane/LP cyl-

 

valve slowly

 

 

inder

 

 

 

2.

Blockage in burner/orifice

2.

Clean burner/replace orifice

 

 

elbow/hose and regulator

 

elbow/hose and regulator

 

 

assembly

 

assembly

 

3.

Battery not installed, battery

3.

Install new alkaline battery

 

 

power low or battery not

 

in electronic ignitor. Verify

 

 

installed correctly

 

battery is installed correctly.

 

 

 

 

See page 10

 

 

 

 

Burner lights but goes out

1. Not enough warm up time

1.

Relight, hold automatic

when automatic control valve

 

 

 

control valve button in 30

button is released

 

 

 

seconds

 

2.

Low gas pressure

2.

Check propane/LP cylinder

 

 

 

 

for proper gas supply

 

3.

Thermocouple loose or

3.

Tighten connection or re-

 

 

needs to be replaced

 

place thermocouple

 

4.

Automatic control valve

4.

Replace automatic control

 

 

needs to be replaced

 

valve assembly

 

5.

Thermocouple gap is too

5.

Maintain 0.17" gap between

 

 

great

 

tip of thermocouple and

 

 

 

 

emitter material

 

 

 

 

Maximum burn rate is low

1. Low gas pressure

1.

Check gas supply; check

 

 

 

 

regulator output

 

2.

Low fuel supply

2.

Consult propane/LP gas

 

 

 

 

supplier

 

3.

Restriction in burner/orifice

3.

Clean burner/replace orifice

 

 

elbow/hose and regulator

 

elbow/hose and regulator

 

 

assembly

 

assembly

6

www.desatech.com

123716-01C