Venting Installation

Continued

Stainless

RTL-8DM

Inner Flue

Chase

Pipe

 

Top

Screen

 

1" Non-

 

 

com-

 

Secure

bustible

1"

Termination

Spacer

Space

to Outer

Apply

Pipe with 3

Waterproof

Screws

Caulking

 

Storm

 

Collar

 

Flashing

Overlap

 

Shingles (Top

Underlap

and Sides of

Shingles

Flashing Base)

 

Figure 25 - Terminations

Chase installations

Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. Terminations must be separated a minimum of 30" center to center and stacked at a minimum vertical height difference of 18" (see Figure 26).

finishing firebox

Installing Firebox Facing

Any noncombustible material may be used for facing (glass, tile, brick, etc.) as long as proper clearances are adhered to and firebox openings are not obstructed in any way (see Figure 27).

Use only heat resistant, noncombustible mortar or adhesive when securing facing material to front of firebox. When placing facing at upper edge of effective opening of firebox, provide “L” shaped piece of metal extending full width of opening (see Figure 27).

Secure with sheet metal screws at a distance high enough from edge so it doesn't interfere with operation of doors. This assures that facing material will not block openings.

Noncombustible

Facing Material

“L” Shaped

Metal Do Not

Support Block

Opening

Noncombustible

Facing Material

Note: If a decorative shroud is to be installed,

 

contact the manufacturer for specifications.

Figure 27 - Fireplace Facing (Your

 

Fireplace May Vary from Illustration)

18"

Min.

Typ.

30" Min.

30" Min.

Figure 26 - Multiple Chase Installation