Venting Installation
Continued
| Vertical Venting |
Note: Install | V = 40' max. |
restrictor into inner | Note: Install restrictor |
collar of fireplace | |
as shown. | into inner collar of |
| fireplace as shown. |
45° Elbow
45°
Elbow
Venting with Two 90° Elbows
Vertical (V1) Horizontal (H)
5' min. | 6' max. |
6' min. | 12' max. |
7' min. | 18' max. |
8' min. | 20' max. |
Note: Vertical (V1) + Vertical (V2) = 40' max.
Figure 23 - Vertical Venting
Configuration Using Two 90° Elbows
(Vertical Round High Wind Termination
Shown)
High Altitude Installation
Your DESA Heating, LLC
Fireplaces for High Altitude (models ending in
When installing a
Figure 24 - Vertical Venting Configuration
With No Horizontal Run (Vertical Round
High Wind Termination Shown)
by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.
IMPORTANT: For horizontal installations above 2,000 feet, it is recommended that a 12" extension pipe be added before starter elbow (see Figure 25, page 18) and a round horizontal termination be used.