Safety

Continued

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

3.Never install the fireplace

in a recreational vehicle

in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front

in high traffic areas

4.Turn fireplace off and let cool before servicing, installing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fire- place inspected annually by a qualified service person.

5.You must keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust

from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

6.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See

Cleaning and Maintenance, page 31.

7.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fire- place nameplate.

8.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

9.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit.

10.Do not operate fireplace if any log is broken.

11.Do not operate fireplace with glass door removed, cracked or broken.

12.Provide adequate clearances around air openings.

Product Identification

Upper Louver Panel

Flue Collar

Nailing Flange

Glass Door Assembly

Lava Rock

Log Set

Lower Louver Panel

 

Burner

 

 

Control Valve with

 

Assembly

Piezo Ignitor

Glowing

 

 

Switch Bracket for Optional

 

Embers

 

Remote and Blower

 

 

Figure 1 - Direct-Vent Fireplace with Millivolt Ignition

4

www.desatech.com

116200-01L