FIREPLACE MANUFACTURERS INC.

UNVENTED PROPANE/LP GAS LOG HEATER

OPERATING

HEATER

Continued

IMPORTANT: This remote control has been specially engineered to take an air temperature sample every 5.5 minutes in the auto mode. It will not respond immediately to the tempera- ture setting being turned up or down.

IMPORTANT: The hand-held remote control unit must be near the heater. Do not keep the hand-held remote control unit too close to the heater. The thermostat on the hand-held re- mote control unit will heat up too quickly and turn the heater off.

3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 26 shows a correct pilot flame pat- tern. Figure 27 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 27

turn heater off (see To Turn Off Gas to Appliance, page 15)

see Troubleshooting, pages 18 through 20

Pilot Burner

Thermocouple

Figure 26 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 27 - Incorrect Pilot Flame Pattern

FRONT BURNER FLAME PATTERN

Figure 28, page 17, shows correct front burner flame pattern. Figure 29, page 17, shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

Control Knob in

Flame

Adjustment

On Position

Knob

 

 

 

 

OL

 

 

 

N

 

 

 

 

 

 

O

F

F

O

 

 

 

 

 

 

 

T

HI

 

 

ON

OLIP

 

 

 

 

 

 

 

 

 

 

OFF

REMOTE

Selector Switch in Remote Position

Figure 24 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

 

Increases Room

Shows

Temperature in

AUTO Mode

Temperature

 

Setting

Decreases Room

 

The Log Heater

Temperature in

AUTO Mode

will Automatically

 

Cycle between

Turns Burners

Pilot and the Heat

On or Off and

Setting that has

Allows You to

been Selected

Choose the Auto

 

 

Setting

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If front burner flame pattern shows yellow tipping, follow instructions at bottom of this page. Yellow flame on rear burner is normal.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by heater, causing brief patches of orange flame.

If front burner flame pattern is incorrect, as shown in Figure 29, page 17.

turn heater off (see To Turn Off Gas to Appliance, page 15)

see Troubleshooting, pages 18 through 20

Figure 24 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA Series Only)

16

105073

Page 16
Image 16
Desa VFP30R, VFP18R, VFP24R installation manual Inspecting Burners, Pilot Flame Pattern, Front Burner Flame Pattern