www.desatech.com 110112-01C
26
Pilot AssemblyLOGS
• If you remove logs for cleaning, refer to Install-ing Logs, page 18, to properly replace logs.• Replace log(s) if broken or chipped (dime-sized or larger).Figure 47 - Cleaning Pilot Air Inlet HolePilot Air Inlet HolePilot BracketCLEANING AND MAINTENANCEContinued
SPECIFICATIONSBtu (Variable) 20,000/33,000Type Gas Natural: VTGF33NRA Propane/LP: VTGF33PRAIgnition Electronic (Automatic)/ Piezo (Manual) Natural Propane/LPManifold Pressure 3.5" W.C. 8.0" W.C.Inlet Gas Pressure (in. of water) Maximum 10.5" 14" Minimum* 5" 11"Shipping Weight 78 lbs. 78 lbs.* For input adjustmentAccess Hole
For Cleaning
PIlot
TROUBLESHOOTING
WARNING: Turn off heater and let cool before servicing. Only a
qualified service person should service and repair heater.
CAUTION: Never use a wire, needle, or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE1. Battery in remote control is ei-
ther missing or has low power
2. Remote control is not pointed
toward fireplace
3. Manual ignition bypass
switch not in OFF position
4. No power available to fire-
place
5. Ignitor electrode not con-
nected to ignitor cable
6. Broken ignitor cable
7. Ignitor electrode broken
8. Ignitor electrode positioned
wrong
REMEDY1. Replace battery in remote
control
2. Point remote control toward
lower front panel of fireplace
when operating
3. Place manual ignition bypass
switch in OFF position
4. Make sure power cord is
plugged into electrical outlet
and outlet has power
5. Reconnect ignitor cable
6. Replace ignitor cable
7. Replace electrode
8. Replace ODS pilot
OBSERVED PROBLEMWhen buttons on remote control
are pressed, there is no response
from fireplace