Specifications
BLUE FLAME MODELS
GWP6
•4,400/6,000 Btu/hr (Variable)
•Propane/LP Gas
•Piezo Ignition
•Pressure Regulator Setting: 8" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 14" wc, Minimum - 11" wc
GWN6
GWP10, GWP10T, MP10T,
VP1000BTA, WMP10
•5,000/10,000 Btu/hr (variable)
•Propane/LP Gas
•Piezo Ignition
•Pressure Regulator Setting: 8" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.
•4,400/6,000 Btu/hr (Variable)
•Natural Gas
•Piezo Ignition
•Pressure Regulator Setting: 3" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 10.5" wc, Minimum - 4" wc
GWN10, GWN10T, MN10T,
VN1000BTA, WMN10
•5,000/10,000 Btu/hr (variable)
•Natural Gas
•Piezo Ignition
•Pressure Regulator Setting: 3" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.
| PLAQUE MODELS |
VP5D | GWRN10, VN10A |
•5,500 Btu/hr
•Propane/LP Gas
•Piezo Ignition
•Pressure Regulator Setting: 8" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.
•5,500/10,000 Btu/hr
•Natural Gas
•Piezo Ignition
•Pressure Regulator Setting: 3.0" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.
VN6D
•6,000 Btu/hr
•Natural Gas
•Piezo Ignition
•Pressure Regulator Setting: 3" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.
VP10TA
•10,000 Btu/hr
•Propane/LP Gas
•Piezo Ignition
•Pressure Regulator Setting: 8" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.
GWRP10, VP10A
•5,500/10,000 Btu/hr
•Propane/LP Gas
•Piezo Ignition
•Pressure Regulator Setting: 8" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.
VN10TA
•10,000 Btu/hr
•Natural Gas
•Piezo Ignition
•Pressure Regulator Setting: 3.5" W.C.
•Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.
26 | www.desatech.com |