Specifications

BLUE FLAME MODELS

GWP6

4,400/6,000 Btu/hr (Variable)

Propane/LP Gas

Piezo Ignition

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure (inches of water): Maximum - 14" wc, Minimum - 11" wc

GWN6

GWP10, GWP10T, MP10T,

VP1000BTA, WMP10

5,000/10,000 Btu/hr (variable)

Propane/LP Gas

Piezo Ignition

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.

4,400/6,000 Btu/hr (Variable)

Natural Gas

Piezo Ignition

Pressure Regulator Setting: 3" W.C.

Inlet Gas Pressure (inches of water): Maximum - 10.5" wc, Minimum - 4" wc

GWN10, GWN10T, MN10T,

VN1000BTA, WMN10

5,000/10,000 Btu/hr (variable)

Natural Gas

Piezo Ignition

Pressure Regulator Setting: 3" W.C.

Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.

 

PLAQUE MODELS

VP5D

GWRN10, VN10A

5,500 Btu/hr

Propane/LP Gas

Piezo Ignition

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.

5,500/10,000 Btu/hr

Natural Gas

Piezo Ignition

Pressure Regulator Setting: 3.0" W.C.

Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.

VN6D

6,000 Btu/hr

Natural Gas

Piezo Ignition

Pressure Regulator Setting: 3" W.C.

Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.

VP10TA

10,000 Btu/hr

Propane/LP Gas

Piezo Ignition

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.

GWRP10, VP10A

5,500/10,000 Btu/hr

Propane/LP Gas

Piezo Ignition

Pressure Regulator Setting: 8" W.C.

Inlet Gas Pressure (inches of water): Maximum - 14" W.C., Minimum - 11" W.C.

VN10TA

10,000 Btu/hr

Natural Gas

Piezo Ignition

Pressure Regulator Setting: 3.5" W.C.

Inlet Gas Pressure (inches of water): Maximum - 10.5" W.C., Minimum - 4" W.C.

26

www.desatech.com

123995-01C