OPTIONAL POSITIONING OF THERMOSTAT SENSING

BULB Continued

thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 43). Slide the thermostat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Thermostat

Sensing Bulb

Adhesive-backed

Mounting Clip

Capillary

Do Not Crimp

Capillary

Figure 43 - Positioning the Thermostat Sensing Bulb in the Vertical Position with the Capillary at the Bottom

Specifications

Dual Burner Biltmore split OAK Models

CCL3018PTA

CCL3018NTA

16,000/30,000 Btu/hr (Variable)

16,000/30,000 Btu/hr (Variable)

Gas Type: Propane/LP

Gas Type: Natural

Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 8" W.C.

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

 

Maximum 14" W.C. Minimum* 11" W.C.

 

Maximum 10.5" W.C. Minimum* 5" W.C.

CCL3924PTA

CCL3924NTA

20,000/39,000 Btu/hr (Variable)

20,000/39,000 Btu/hr (Variable)

Gas Type: Propane/LP

Gas Type: Natural

Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 8" W.C.

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

 

Maximum 14" W.C. Minimum* 11" W.C.

 

Maximum 10.5" W.C. Minimum* 5" W.C.

* For the purpose of input adjustment

Single Burner SEASONAL OAK Models

CRL2718PA

CRL2718NA

16,000/27,000 Btu/hr (Variable)

16,000/27,000 Btu/hr (Variable)

Gas Type: Propane/LP

Gas Type: Natural

Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 8" W.C.

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

 

Maximum 14" W.C. Minimum* 11" W.C.

 

Maximum 10.5" W.C. Minimum* 5" W.C.

CRL3124PA

CRL3124NA

16,000/31,500 Btu/hr (Variable)

16,000/31,500 Btu/hr (Variable)

Gas Type: Propane/LP

Gas Type: Natural

Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 8" W.C.

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

 

Maximum 14" W.C. Minimum* 11" W.C.

 

Maximum 10.5" W.C. Minimum* 5" W.C.*

For the purpose of input adjustment

30

www.desatech.com

113097-01L