26

Storage

warning

During operation the muffler or catalytic muffler and surrounding cover becomes hot. Always keep exhaust area clear of flammable debris during transportation or when storing, otherwise serious property damage or personal injury may result.

Long Term Storage (Over 30 Days)

Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage maintenance which includes the following:

1.Store unit in a dry, dust free place, out of the reach of children.

danger

Do not store where fuel fumes may accumulate or reach an open flame or spark.

2.Place the stop switchs in the "STOP" position.

3.Remove accumulation of grease, oil, dirt and debris from exterior of unit.

4.Perform all periodic lubrication and services that are required.

5.Tighten all screws and nuts.

6.Drain the fuel tank completely and pull the recoil starter handle several times to remove fuel from the carburetor.

7.Remove the spark plug and pour 7cc (1/4 oz.) of fresh, clean ECHO 2-stroke engine oil into the cylinder through the spark plug hole.

A.Place a clean cloth over the spark plug hole.

B.Pull the recoil starter handle 2-3 times to distribute the oil inside the engine.

C.Observe the piston location through the spark plug hole.Pull the recoil handle slowly until the piston reaches the top of its travel and leave it there.

8.Install the spark plug (do not connect ignition cable).

9.Remove blower/vacuum pipes from unit.