82
5
X301
1
6
X308
8
X302
2
230V
7
4
X312
X311 3
TX
RX
Tacho
GND
3
6661
Motor and motor control
Function
DANGER
Be careful when measuring the electric components in the motor
control. All components have a potential difference of approx. 300 V
in relation to protective earth and neutral.
When the green LED on the motor control card is lit, the compo-
nents carry dangerous voltages.
The motor control lose all voltage about 10-30 seconds after the
voltage has been disconnected and the motor has stopped.
The motor control communicates with the programme unit via a serial two-
wayinterface.Withthehelpofthemotorcontrol,theprogrammeunitcan
control not only the instantaneous motor rpm, but also with high precision
theaccelerationandretardationofthemotorinordertoreachthetarget
rpm.Themotorcontrolcontinuouslyreplieswithinformationtothepro-
grammeunitPCBregardingthecurrentoperatingstateandsendsreports
ifanerroroccurs.
1. Voltagesupply
2. Doorlockswitch
3. Feed, motor
4. Motor
5. ProgrammeunitA1
6. MotorcontrolU1
7. Tacho signal
8. Imbalanceswitch
3