Asianux AX [x86_64]
No. Host System Operating
System Host
Bus Host Bus Adapter Topology Storage
Array External
Boot Comments
23 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850,
6800, 6850;
HPQ Proliant: DL380 (G4), DL580 (G3)51, ML370
(G4)51;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express Emulex LPe1150−E6, 8, 9, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
24 Dell PowerEdge: 1800, 2800, 2850 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express Emulex: LP1050−E6, 8, 23, 42, LP982−E6, 23,
50;
QLogic QLA2340−E−SP6, 41, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
25 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850,
6800, 6850 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express Emulex: LP1050Ex−E6, 8, 23, 42, LPe111−E6,
8, 23, 47, 48;
QLogic: QLE2360−E−SP6, 37, 46, 49,
QLE2460−E−SP6, 17, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
26 Dell PowerEdge 1950 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express QLogic QLE220−E−SP6, 44, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
27 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950;
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
Emulex LP101−E6, 8, 23, 42;
QLogic: QLA200−E−SP6, 38, 49,
QLA210−E−SP6, 38, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
28 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950;
HPQ Proliant: DL320 (G5), DL360 (G5), DL385
(G2), DL585 (G2), ML350 (G5)51, ML370 (G5)51,
ML570 (G4)51
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
Emulex LP1050−E6, 8, 23, 42 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
29 HPQ Proliant: DL320 (G5), DL360 (G5), DL385
(G2), DL585 (G2), ML350 (G5)51, ML370 (G5)51,
ML570 (G4)51;
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
Emulex LP1050−E8, 23, 42;
HPQ: AB429A/FC1143 (QLA2460)6, 17, 49,
AE369A/FC1243 (QLA2462)6, 17, 49;
QLogic QLA2462−E−SP6, 17, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
30 Hewlett Packard Proliant ML350: (G4), (G4p) Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
Emulex LP982−E23, 50;
QLogic: QLA2340−E−SP41, 49,
QLE220−E−SP6, 17, 45
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
31 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6800, 6850, 6950 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
Emulex LP982−E6, 23, 50;
QLogic QLA2340−E−SP6, 41, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
32 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6950;
HPQ Proliant: DL320 (G5), DL360 (G5), DL385
(G2), DL585 (G2), ML350 (G5)51, ML370 (G5)51,
ML570 (G4)51
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
Emulex LPe1150−E6, 8, 9, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
33 Dell PowerEdge: 1950 III, 2900, 2900 III, 2950,
2950 III, 2970, 6950 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
Emulex: LP1050Ex−E6, 8, 23, 42, LPe111−E6,
8, 23, 47, 48;
QLogic: QLE2360−E−SP6, 37, 46, 49,
QLE2460−E−SP6, 17, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
34 HPQ Proliant: DL320 (G5), DL360 (G5), DL385
(G2), DL585 (G2), ML350 (G5)51, ML370 (G5)51,
ML570 (G4)51
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
HPQ: A8002A/FC2142SR (LPe1150)6, 8, 9,
23, AE311A/FC1142SR (QLE2460)6, 17, 49,
AE312A/FC1242SR (QLE2462)6, 17, 49
FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
35 NEC Express 5800: 120Li, 120Rg−1, 120Ri−2,
140Hf, 140Re−4 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
NEC N8190−120 (LP1050)8, 23, 54, 55 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
36 NEC Express 5800: 120Li, 120Lj, 120Rh−1,
120Rj−2 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
NEC N8190−120 (LP1050)8, 23, 55, 57 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
37 NEC Express 5800: 120Li, 120Lj, 120Rg−1,
120Rh−1, 120Ri−2, 120Rj−2, 140Hf, 140Re−4 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
NEC: N8190−127 (LPe1150)8, 9, 22, 23,
N8190−131 (LPe11002)8, 9, 23 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
38 HPQ Proliant: DL320 (G5), DL360 (G5), DL385
(G2), DL585 (G2), ML350 (G5)51, ML370 (G5)51,
ML570 (G4)51;
Hewlett Packard Proliant DL360: (G4), (G4p);
Hewlett Packard Proliant ML350: (G4), (G4p)
Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
QLogic QLA2460−E−SP6, 17, 49 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
39 Dell PowerEdge: 1850, 1900, 1950 III, 2850, 2900,
2900 III, 2950, 2950 III, 2970, 6800, 6850, 6950 Asianux
AX
[x86_64]
2.0 SP24,
20, 21
PCI
Express,
PCI−X
QLogic QLE220−E−SP6, 44, 45 FC−AL,
FC−SW EMC
CLARiiON
AX150
Y
CLARiiON AX150
03/04/2009 43 CLARiiON AX150