1 Introduction

This software manual describes step by step how to operate successfully with the ½ 19"

and 19" MLT analyzer module and analyzer of the NGA 2000 Series. Chapter two shows the structure of the MLT software menus. Chapter three describes the display and the keyboard of the analyzer. Chapter four describes the basic controls with detailed illustrations. So you can easily compare the actual display of the analyzer module with the illustrations of the manual.

Chapter five describes the expert configurations of the analyzer module and of the Input/ Output Modules (I/O modules). Chapter six describes the system configuration. The layout of both chapters is not as detailed as in chapter four. Normally, the way to a certain menu of the MLT software is described with the software catchwords you have to press to reach this menu. You will find the illustration of the corresponding LCD screen at the end of the catchword listing. After that you can read the meaning of the functions and variables of each expert or system configuration menu.

Some contents of the expert configurations are not important for each customer. It depends on the configuration of your NGA 2000 system, relative to the following components:

Control Module

CM

Analyzer Module

AM

Input/Output Modules I/O's (SIO =Standard I/O, DIO = Digital I/O,

System Auto Calibration I/O, Analog Output with 3 Alarms I/O,

Auto Calibration I/O)

You can distinguish the following system units and SIO/DIO configurations:

System Unit

SIO/DIO-Configuration

Section

Page

 

 

MLT analyzer module (AM):

1 local SIO and 1 local DIO can be

 

without front panel,

installed in the MLT analyzer

 

module

 

i.e. without control unit

5.1.18

SIO and DIO can be configured

can be combined with a platform,

p. 5-67

for the channels of the analyzer

an MLT analyzer, a TFID analyzer

 

module only

 

or a customer developed control

 

 

 

unit

 

 

Platform (CM Software):

1 SIO and up to 4 DIO's can be

 

Control unit with front panel

installed in the platform (CM I/O)

5.2

SIO and DIO can be configured

Without measurement channels

p. 5-83

for all channels combined with the

 

 

 

platform

 

MLT analyzer (CM and MLT AM

1 SIO and 1 DIO can be installed

 

software):

in the MLT analyzer (CM I/O)

 

Analyzer with front panel

SIO and DIO can be configured

5.2

 

CM and AM software in the same

for all channels combined with the

p. 5-83

MLT analyzer

analyzer,

 

 

 

i.e. all functions of the control unit

 

 

and of the AM are combined in one

 

 

controller board

 

 

90003482(2) [NGA-e (MLT-Software 3.2.X)] 07/98

NGA 2000

1 - 1