3Installation Instructions and Owner’s Manual
Unvented LP-Gas Vent Free Room Heaters
9. Operating heater above elevations of 4,500 feet
could cause pilot/ODS to shutdown heater.
10. Always run heater with control knob in a locked po-
sition. Never set control knob between locked posi-
tions. Poor combustion and higher levels of carbon
monoxide may result if control knob is left between
locked positions.
DANGER: Carbon monoxide poisoning may lead to
death.

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning resemble the
u, with headaches, dizziness, or nausea. If you have
these signs, the heater may not be working properly.
Get fresh air at once! Have heater serviced. Some
people are more affected by carbon monoxide than oth-
ers. These include pregnant women, persons with heart
or lung disease or anemia, those under the inuence of
alcohol, and those at high altitudes.

Propane/LP Gas:

Propoane/LP gas is odorless. An odor making agent is
added to propane/LP gas. The odor helps you detect
a Propane/LP gas leak. However the odor added to
propane/LP gas may be present even though no odor
exists. Make certain you read and understand all warn-
ings. Keep this manual for reference. It is your guide to
safe and proper operation of this heater.
PRECAUTIONS:
1. BF-20 LPT, BF-30 LPT, IR-20 LPT and IR-30 LPT
may not be installed in a bedroom or bathroom, or
any place where a strong wind would shut down the
appliance.
2. This heater needs outside ventilation air to run
properly. The Oxygen Depletion Sensor (ODS)
safety shutoff system shuts down the heater if not
enough fresh air is available. See Fresh Air for
Combustion and Ventilation, pages 5 through 6.
3. Keep all air openings in heater clear, free of debris
or any blockage. This will insure that enough air for
proper combustion enters the heater.
4. If heater shuts off, do not relight until you provide
fresh, outside air. If heater keeps shutting off, it
requires servicing.
5. Turn off and unplug heater and let cool before
servicing. Only a qualied service person should
service and repair heater.
6. Do not run heater:
• Where ammable liquids or vapors are used or
stored
• During dusty conditions.
7. Before using furniture polish, wax, carpet cleaner
or similar products, turn heater off. If heated the
vapors from these products may create a white
powder residue within burner box or on adjacent
walls or furniture.
8. Do not use heater if any part has been underwater.
Immediately call a qualied service technician to
inspect the room heater and to replace any part of
the control system and any gas control which has
been underwater.
SPECIFICATIONS
IR20LPT IR30LPT BF20LPT BF30LPT
BTU (Available) 20,000 30,000 20,000 30,000
Type of Gas LP-Gas Only LP-Gas Only LP-Gas Only LP-Gas Only
Ignition Battery ignitor (1-AA) Battery ignitor (1-AA) Battery ignitor (1-AA) Battery ignitor (1-AA)
Pressure Regulator Setting 10 Inches of Water 10 Inches of Water 10 Inches of Water 10 Inches of Water
Inlet Gas Pressure (Maximum) 14 Inches of Water 14 Inches of Water 14 Inches of Water 14 Inches of Water
Inlet Gas Pressure (Minimum) 11 Inches of Water 11 Inches of Water 11 Inches of Water 11 Inches of Water
Electrical Rating /Blower 120V, 60Hz , 1 120V, 60Hz , 1 120V, 60Hz , 1 120V, 60Hz , 1
Burners / Orice nozzles 3 4 1 1
Thermostatic Control Yes Yes Yes Yes
Clearances: inches (mm)
Top 36” (915cm) 36” (915cm) 36” (915cm) 36” (915cm)
Sides 10.5” (267cm) 10.5” (267cm) 10.5” (267cm) 10.5” (267cm)
Floor (min to top of carpet) 2” (51cm) 2” (51cm) 2” (51cm) 2” (51cm)
Fabric / ammable objects 36” (915cm) 36” (915cm) 36” (915cm) 36” (915cm)