Initial Installation
WARNING: Operation of this heater when not connected to a properly installed and maintained
venting system can result in carbon monoxide (CO) poisoning and possible death.
CLEARANCES TO COMBUSTIBLES:
Maintain sufcient clearances for operation, service and maintenance.
• A clearance of 25 ” (648 mm) minimum is required from the center of the unit to the sidewalls.
10"(254mm) Mantle
2"(51mm)
Mantle
39"(991 mm)
minimumto
bottomof unit
43"(1092 mm)
minimumto
bottomof unit
Figure 16: Mantle width and height.
• A 2” (51 mm) wide mantel can be mounted at a
minimum height of 39” (991 mm) from the bottom
of unit.
• A 10” (254 mm) wide mantel can be mounted at a
minimum height of 43” (1092 mm) from the bottom
of unit.
• If installed at oor level, a minimum 16” (406 mm)
non-combustible material must be installed in front
of the unit.
• If installed on a 12” (305 mm) wide hearth raised a
minimum height of 6” (152 mm), no oor protection
is required.
• Refer to Figure 17 for additional required oor
protection dimensions with different width hearths.
Sienna
0"(0mm)
5"(127mm)
6"(152mm)
7"(178mm)
8"(203mm)
9"(229mm)
10"(254mm)
11"(279mm)
12"(305mm)
13"(330mm)
14"(356mm)
15"(381mm)
16"(406mm)
HearthHeight
of6" (152mm)
Non-combustible
floorprotection required
infront of corresponding
hearthwidth
6"(152mm)
11"(279mm)
12"(305mm)
EXAMPLE:If the Sienna is raised
6"(152mm) and has 4" (102mm)
widehearth in front of it then 12"
(305mm)of non-combustible
floorprotection is require to
beinstalled in front of the
hearth.
Figure 17: Floor protection distance required.
13