
Afirestop
isrequired
throughthe
rearwall.
23"
(584mm)
135/8"
(346mm)
61"(1.55m)
minimum
withinthe framing
(behindthe finish
facing)from the
baseof the unit
&
54"(1.37m)
minimum
ceilingheight in
frontof the unit
fromthe base
ofthe unit
401/4"
(1022mm)
Min61/2"
(165mm)
Ceiling
Figure 17. Dimensions for Framing the Firebox.
Werecommend
installingthese
framepieces
afterthe unit
isinstalled.
123/8"
(315mm)
55/16"
(135mm)
45o
3415/16"
(887mm)
401/4"
(1022mm)
Table 2. Framing Dimensions.
Firebox Framing
Depth 13” 34.6 cm
Width 23” 58.4 cm
Height 40” 102.2 cm
Figure 18. Dimensions for Top
Framing the Firebox.
The replace can be located along
a wall, raised or at oor level, or in
a corner. There are specic framing
measurements for each situation.
The basic opening should have the
dimensions shown in Figure 17 and
Table 2. Refer to Figure 1 and Table
3 for the placement of the gas and
electrical inlets. When the basic framing
is done and the unit is installed the three
(3) top pieces of the framing p]pi T] plac]rMRern0 ØØ#6ØØB6B•••66##66f&sideInle:GaElericam63/16158c821.5cDisaceu]