3.2.5.5 CR Motor Removal

1. Remove the printer mechanism (see Section 3.2.4).
2. Release the timing belt (see section 3.2.5.2).
3. Remove the 3 screws securing the CR motor to the upper frame, and then remove the CR
motor.

3.2.5.6 PF Motor Removal

1. Remove the printer mechanism (see Section 3.2.4).
2. Remove the 2C BN(M3×6) screws and then remove the PF motor.
CR Motor
Screws
Figure 3-15. CR Motor Removal
CBS (M3x6)
PF Motor
Figure 3-16. PF Motor Removal
Stylus Pro XL Disassembly and Assmbly