PSB No:
Page: 4 of 4
03 A ‘Verify After Write” check to the SRAM has failed. The SRAM could be bad.
10This is a motor control error. Four possible areas of failure are:
a.CR home condition not detected at power up
b.Platen gap motor HP not detected correctly
c.Friction/Tractor feed switching error
d.Physical obstruction such as a jammed ribbon
11Skewed paper detect error. Since the initial reading upon loading a single sheet paper, the paper has skewed. This is a printhead wire protection feature.
12Illegal paper positioning.
(1)If the paper is loaded using the knob instead of the LOAD/EJECT switch, this error condition will occur. This is a printhead wire protection feature.
(2)PE sensor may have failed or is not connected.
20 CPU error. An undefined
NOTES: Error codes 11 and 12 are usually caused by new operators who are
Incorrect jumper settings on the ROMA board may cause errors 10 or
20.The correct settings are documented in the Service Manual (page
Errors 0,2, 3, 10, and 20 may require a repair, adjustment or replacement.