Troubleshooting - 79
Lamp Indicator
Temperature Indicator
Extinguished The power is not
switched on
The power is not switched on.
·Check to ensure that the lamp or fan are
correctly attached if the lamp has been
replaced. If the lamp or fan are not correctly
attached, the projector will assume the same
status as if the power has not been switched
on.
·Check the power cord connection.
Check the power supply to the socket.
39
Indicator Status Cause Recovery and Status Reference
Page
Blinking in Red Lamp error ·Replace with a new lamp (ELPLP11).
·If the lam p is bro ken, t ake ca re to av oid in jury
and contact your nearest adress provided at
page 104 to request repairs (images cannot be
projected unless the lamp is replaced).
91
Blinking in
Orange
Nearing the time
for replacing the
lamp
Prepare a new lamp. It is recommended that
the lamp is replaced as soon as possible, as
there are cases where the time for replacement
is earlier than stated in the conditions of usage.
91
Extinguished (Not an error)
The power has not been switched on or nor-
mal projection is in progress.
Indicator Status Cause Recovery and Status Reference
Page
Illuminated in
Red
Excesive internal
temperature
(overheating)
·Use the projector within the permissible
temperature range of between 5 degrees
Celsius and 40 degrees Celsius.
·Install the projector in a well-ventilated place
and ensure that the ventilation inlet and
outlet are not blocked.
22
·Clean the Air Filter.
·Switch the lamp off when the red lamp is
illuminated to reduce the temperature inside
the projector.
89
Blinking in Red Internal error Cease operations, remove the Power Plug
from the socket and contact your dealer or
nearest adress provided at page 104 and
request repairs.
Indicator Status Cause Recovery or Status Reference
Page