Troubleshooting - 75

Temperature Indicator
Point

·Refer to the section on [When the Indicators Provide No Help] on the following page if the

Indicators appear normal but the projected image is defective.

·Contact your dealer if an Indicator status not covered by the above table is apparent.

Indicator Status Cause Recovery and Status Reference
Page
Illuminated in Red Excesive internal
temperature
(overheating)
·Use the projector within the permissible
temperature range of between 5 degrees
Celsius and 40 degrees Celsius.
·Install the projector in a well-ventilated place
and ensure that the ventilation inlet and
outlet are not blocked.
23
·Clean the Air Filter. 84
Blinking in Red Internal error Cease operations, remove the Power Plug
from the socket and contact your dealer or
nearest address provided at page 96 and
request repairs .
Blinks in orange High-temperature
cooling in progress
·(This is not an error, but the projector will
automatically cease operating if the
temperature increases any further.)
·Use the projector within the permissible
temperature range of between 5 degrees
Celsius and 40 degrees Celsius.
·Install the projector in a well-ventilated place
and ensure that the ventilation inlet and
outlet are not blocked.
23
·Clean the Air Filter. 84
Extinguished (Not an error)
The power has not been switched on or nor-
mal projection is in progress.