Software-based Configuration and Control, cont’d
IPL 250 • Software-based Conguration and Control
3-16
Unit 2’s Port Settings internal Web page
3. Choose the serial port (on the local IPL 250, unit 2) that you wish to
communicate through.
4. For Serial Bridging, click the On radio button to activate bridging mode.
5. In the Remote IP Address field, type in the IP address of unit 1.
6. In the Remote TCP Port field, type in the number (2001-2003) for the serial
port on unit 1 that is to be used in the virtual connection.
7. Click the Submit button.
The A/V device attached to remote unit 1 should now accept all serial commands
from your PC, touchpanel, or controller.
Saving and uploading the configuration
This is not an advanced configuration function, but when you finish creating the
configuration in Global Configurator, you must save the GC project and upload the
configuration to one or more IPL 250 units. See chapter 3 of the IPL 250 Setup Guide
(shipped with the IPL) or the Global Configurator Help file for instructions.
Controlling an IPL 250
You can control the IPL and devices connected to it by using a shared network and
one or more of the following tools: