2-3SW RGBHV Series Switchers • Installation
SW2 models
1. If rubber feet were installed on the bottom of the switcher, remove them.
2. Place the switcher on one half of the optional RSU 129 or RSB 129 1U (one
unit high, 19" wide) rack shelf (part #60-190-01 or 60-604-02). Align the front
of the switcher with the front of the shelf, and align the threaded holes on the
bottom of the switcher with the holes in the rack shelf (figure 2-1).
(2) 4-40 x 3/16" Screws
Use 2 mounting holes on
opposite corners.
False front panel
uses 2 front holes.
RGBHV & AUDIO SWITCHER
AUTO SWITCH
ACUTIVE
SW2 RGBHV A
2
1
AUDIO
CONF/SAVE
-dB+dB
Figure 2-1 — Rack mounting an SW2 switcher
3. Secure the switcher to the rack shelf with the two provided 4-40 x 3/16"
machine screws. Insert the screws from the underside of the shelf, and
securely fasten them through diagonally opposite corners as shown in
figure 2-1.
4. Fasten the false front panel (provided with the rack shelf) to the unoccupied
side of the rack (as shown in figure 2-1), or install a second half-rack-width
device in that side by repeating steps 1 through 3.
5. Secure the rack shelf to the rack using four 10-32 x ¾" bolts. Insert the bolts
through the provided #10 beveled washers, then through the holes in the rack
ears.