SIDEBURNER PARTS LIST

Item

Part

Description(Qty.)

No.

No.

 

 

1.

3275-06

 

Handle assembly

2.

3275-04

 

Lid, porcelain

OR 3280-04

 

Lid, S.S.

3.

3275-26

 

Lid stop (2)

4.

3275-10

 

Burner grid

5.

3005

 

Valve, w/o knob

6.

3020

 

Knob

7.

3275-39

 

Valve manifold assembly

8.

3275-35

 

Gas connector tube

9.

3275-32

 

Side burner assembly, complete

 

Comprising of:

 

 

9A

Orifice housing

 

9B

Ignitor electrode

 

9C

Venturi tube

 

9D

Lock nut

 

9E

Burner base

 

9F

Burner cap

10.3001-49-1 Burner orifice, nat gas #49

 

OR 3001-56-1

Propane gas #56

11.

3199-32

Ignitor spark generator

1

2

4

9 F

9 C

9

 

9 D

 

 

9 E

3

6

 

 

9 B

 

10

9 A

11

8

5

7

PREPARING FOR INSTALLATION OFYOUR FIRE MAGIC SIDE BURNER

Your Fire Magic Sideburner is designed to complement your Fire Magic Barbecue. It provides a convenient, efficient cooking surface for side dishes that require bottom heat only.

TOOLS REQUIRED: A pair of wrenches, pliers or vice grips for the gas connection.

CODE AND SUPPLY REQUIREMENTS: This burner must be installed in accordance with local codes and ordinances or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.

This appliance and its individual shutoff valve must be disconnected from the gas supply piping system when testing the system at pressures in excess of 1/2 psig.

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply system at pressures up to and including 1/2 psig.

WHERE TO INSTALL YOUR SIDEBURNER

Fire Magic Sideburners are designed for outdoor use only.

WARNING: Sideburners must be installed in masonry or other type of fireproof enclosure. The unit is not insulated and therefore must be installed with 18" of side and back clearance from unprotected combustible materials such as wood, plastic, or stucco with wood framing. Do not install under overhead unprotected flammable construction. A 4" clearance to any back wall is required to open the lid properly.

This is a drop-in type unit. The unit must be removable for gas hookup, servicing and burner adjustment.

PROPER VENTILATION: Proper ventilation of your sideburner must be maintained to ensure proper performance. Do not operate with lid closed.

VENTILATION OF ENCLOSURES

When using propane gas, take EXTREME CAUTION to ensure ample ventilation of gas vapor. Propane vapor is invisible and heavier than air. A DANGEROUS EXPLOSION could occur, resulting in SERIOUS INJURY, OR LOSS OF LIFE if propane gas is allowed to accumulate and then ignite.

2