APPENDIX
CONFIGURATIONS OF TERMINALS
MONITOR OUT TERMINAL (ANALOG)
Terminal :
Pin Configuration |
| 1 | Red Input | 9 | +5V Power | ||||
|
|
|
|
| 2 | Green Input | 10 | Ground (Vert.sync.) | |
5 | 4 | 3 | 2 | 1 | 3 | Blue Input | 11 | Sense 0 | |
4 | Sense 2 | 12 | DDC Data | ||||||
10 | 9 |
| 8 | 7 6 | |||||
15 | 14 | 13 | 12 | 11 | 5 | Ground (Horiz.sync.) | 13 | Horiz. sync. | |
|
|
|
|
| |||||
|
|
|
|
| 6 | Ground (Red) | 14 | Vert. sync. | |
|
|
|
|
| 7 | Ground (Green) | 15 | DDC Clock | |
|
|
|
|
| 8 | Ground (Blue) |
|
|
Pin Configuration
C1 C2
1 2 3 4 5 6 7 8
9 101112131415161718192021222324
C3 C4
C5
C1 Analog Red Input
C2 Analog Green Input
C3 Analog Blue Input
C4 Analog Horiz. sync
C5 Analog Ground (R/G/B)
1 | T.M.D.S. Data2– | 9 | T.M.D.S. Data1– | 17 | T.M.D.S. Data0– |
2 | T.M.D.S. Data2+ | 10 | T.M.D.S. Data1+ | 18 | T.M.D.S. Data0+ |
3 | T.M.D.S. Data2/4 Shield | 11 | T.M.D.S. Data1/3 Shield | 19 | T.M.D.S. Data0/5 Shield |
4 | +3.3V MCI | 12 | +5V MCI | 20 | Viewer RXD |
5 | 13 | Card In | 21 | Viewer TXD | |
6 | DDC Clock | 14 | +5V Power | 22 | T.M.D.S. Clock Shield |
7 | DDC Data | 15 | Ground (for +5V) | 23 | T.M.D.S. Clock+ |
8 | Analog Vert. sync | 16 | Hot Plug Detect | 24 | T.M.D.S. Clock– |
44