Fireplace Installation
Continued
Mantels
A mantel may be installed if desired (see Figure 4). Woodwork such as wood trims, mantels or any other combustible material projecting from front face must not be placed within 12" of fireplace opening (and within 9" of top louver opening). Combustible materials above 12" and projecting more than 1 1/2" from fireplace must not be placed less than 12" from top opening of fireplace (NFPA STD 211, Sec.
Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front face falls within limits shown in Figure 5.
| 12 1/4" Ref. | Combustible | |
|
|
| Material |
6" |
|
| Safe Zone For |
|
| Projection of | |
Ref. | 33° |
| Combustible |
|
| Materials | |
|
|
| |
| 3" Nom. | *Note: Drawing | |
|
|
| Not To Scale |
15" |
| 1 1/2" |
|
Min. |
|
| |
9" | Max. |
| |
|
| ||
| 12" Min. |
|
|
| Min. |
|
|
| Top of | Upper Section | |
| Louvered | ||
| of Circulating | ||
| Opening | ||
| Fireplace | ||
|
|
| |
| Fireplace Opening |
|
Figure 4 - Mantel Clearances to
Combustible Material
FIREBOX
Top View of Fireplace
0.625" Max.
| 8" | SAFE ZONE |
| 1" | |
33° |
| |
|
|
Min. 12" from
Perpendicular Side Wall
Figure 5 - Side Mantel Clearance
Fan/Blower Kit assembly
Fan or blower kit is optional with this fireplace (for circulating models only). Use of blowers or fans other than those manufactured by FMI PRODUCTS, LLC voids warranty. Fan is operated by pressing rocker switch (see Figure 6) in lower right hand corner of fireplace face. Blower is operated by turning control knob (not shown).
Fan/blower kit electrical connections are made through electrical cover plate on side of fireplace a shown in Figure 6.
Rocker | Electrical | Electrical | ||
Switch | Bushing | Cover | ||
Plate | ||||
|
|
| ||
Electrical | Wire Nut (3x) | Outer Wrapper | ||
|
| |||
Housing | (Not Supplied) of Fireplace | |||
| Power Source Wiring | |||
|
| |||
|
| (Not Supplied) | ||
|
|
| To Power | |
|
|
| Source |
Electrical Cover
Plate and
ReceptacleElectrical Bushing (Supplied)
Fireplace Chassis
Prewired Receptacle Ground
and Ground
Figure 6 - Fan
Wiring Instructions
1.Remove electrical cover plate with bush- ing from fireplace by removing 2 sheet metal screws as shown in Figure 6.
2.Slide power source wiring through electri- cal bushing opening and electrical cover plate and make all necessary connec- tions.
3.Slide all wiring connections in electrical housing as shown in Figure 6.
4.Secure electrical cover plate with screws previously removed.
Note: Electrical housing and cover plate have sharp edges. Wear protective gloves.
6 | www.fmiproducts.com |