www.fmiproducts.com 122638-01E8
Figure 8 - Fireplace Settings (Default
Settings are Circled)
CLEANINg ANd MAINTENANCE

WARNING: Always discon-

nect power and allow the heater

to cool before performing any

cleaning, maintenance or reloca-

tion of this heater. Turn controls

to OFF and remove plug from

outlet or turn off circuit breaker

to heater.

To service electric replace it may be neces-
sary to remove it from the mantel or enclosure
in which it is installed. Let unit cool completely
before cleaning or servicing.

CLEANING FIREBOx

1. Open control panel door by pressing on
right side. A spring magnet will push door
forward. Pull door down to open.
2. Remove 2 screws holding front trim in
place. Pull gently to remove trim (see
Figure 9). There are magnets on the lower
portion of trim (see Figure 9)
3. With gloves and safety glasses in place,
remove 4 screws from glass retainer
brackets (see Figure 9).
4. Carefully remove front glass and brackets
(see Figure 10).
5. Using a brush vacuum attachment, gently
clean compartment.
6. After cleaning compartment, replace front
glass, brackets and trim.
Figure 10 - Removing Brackets and Front
Glass
Bracket
Front Glass
Figure 9 - Removing Trim
Magnets on
Back of Trim
Screws
Bracket
Trim
Control Panel Door
oPERATIoN
Continued
HEATER Off Low Medium High
FLAME Off Low Medium High
EMBER Off Low Medium High
BACKLIGHT Off Low High
Figure 7 - Remote Control For Electric
Fireplace
Glass Bracket
Screws
3. When using remote control, aim remote
at sensor located in center of unit just
above log set. IMPORTANT: This remote
control must remain within 20 feet (6 m)
of replace to be effective.
4. When power switch is turned off, replace
settings go back to default (see Figure 8).