Sheet
Metal
Screws

FIREPLACE INSTALLATION

Continued

MANTELS

A mantel may be installed if desired (see Figure 4). Woodwork such as wood trims, mantels or any other combustible material projecting from front face must not be placed within 12" of fireplace opening (and within 9" of top louver opening). Combustible materials above 12" and projecting more than 1 1/2" from fireplace must not be placed less than 12" from top opening of fireplace (NFPA STD 211, Sec. 7-3.3.3).

Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front face falls within limits shown in Figure 5.

 

12 1/4" Ref.

Combustible

 

 

 

Material

6"

 

 

Safe Zone For

 

 

Projection of

Ref.

33°

 

Combustible

 

 

Materials

 

 

 

 

3" Nom.

*Note: Drawing

 

 

 

Not To Scale

15"

 

1 1/2"

 

Min.

 

 

9"

Max.

 

 

 

 

12" Min.

 

 

 

Min.

 

 

 

Top of

Upper Section

 

Louvered

 

of Circulating

 

Opening

 

Fireplace

 

 

 

 

Fireplace Opening

 

Figure 4 - Mantel Clearances to

Combustible Material

FIREBOX

Top View of Fireplace

0.625" Max.

 

8"

SAFE ZONE

33°

1"

 

 

 

Min. 12" from

Perpendicular Side Wall

Figure 5 - Side Mantel Clearance

FAN/BLOWER KIT ASSEMBLY

Fan or blower kit is optional with this fireplace (for circulating models only). Use of blowers or fans other than those manufactured by FMI PRODUCTS, LLC voids warranty. Fan is operated by pressing rocker switch (see Figure 6) in lower right hand corner of fireplace face. Blower is operated by turning control knob (not shown).

Fan/blower kit electrical connections are made through electrical cover plate on side of fireplace a shown in Figure 6.

Rocker

 

Electrical

Electrical

Switch

 

Bushing

Cover

 

Plate

 

 

 

 

Electrical

Wire Nut (3x)

Outer Wrapper

Housing

(Not Supplied)

of Fireplace

 

 

Power Source Wiring

 

 

 

 

 

 

(Not Supplied)

 

 

 

 

To Power

 

 

 

 

Source

 

 

 

Electrical Cover

Receptacle

 

Plate and

 

Electrical Bushing

(Supplied)

 

Fireplace Chassis

Prewired Receptacle

Ground

 

and Ground

 

 

 

Figure 6 - Fan Switch-Electrical Bushing

Wiring Instructions

1.Remove electrical cover plate with bush- ing from fireplace by removing 2 sheet metal screws as shown in Figure 6.

2.Slide power source wiring through electri- cal bushing opening and electrical cover plate and make all necessary connec- tions.

3.Slide all wiring connections in electrical housing as shown in Figure 6.

4.Secure electrical cover plate with screws previously removed.

Note: Electrical housing and cover plate have sharp edges. Wear protective gloves.

6

www.fmiproducts.com

109036-01M