Product Specifications

 

GAS RATING - NATURAL

 

 

M36E(B,H), VM36E(B,H)

M42E(B,H), VM42E(B,H)

Max. Input Rating:

40,000 Btu/Hr

45,000 Btu/Hr

Manifold Pressure:

3.5" WC (.87 kPa)

3.5" WC (.87 kPa)

Minimum Supply Pressure:

4.5" WC (1.12 kPa)

4.5" WC (1.12 kPa)

Maximum Supply Pressure:

10.5" WC (2.66 kPa)

10.5" WC (2.66 kPa)

Orifice Size:

# 30

# 29

GAS RATING - PROPANE/LP

 

 

M36P(B,H), VM36P(B,H)

M42P(B,H), VM42P(B,H)

Max. Input Rating:

40,000 Btu/Hr

45,000 Btu/Hr

Manifold Pressure:

10" WC (2.49 kPa)

10" WC (2.49 kPa)

Minimum Supply Pressure:

11" WC (2.74 kPa)

11" WC (2.74 kPa)

Maximum Supply Pressure:

13" WC (3.23 kPa)

13" WC (3.23 kPa)

Orifice Size:

# 52

# 50

For Use With

A

 

 

 

6"Ø Type B-1

 

 

Vent Pipe Only

 

 

Stand Off

 

 

Collar

7"

 

B

C

 

 

 

7"

Alternate Gas

Supply Inlet

 

X

 

 

 

 

K

 

Outside Air

 

 

Kit Location I

J

 

(Optional)

 

R

T

7"

 

P

S

 

Q

 

 

 

F

EHEARTH AREA

DIMENSIONS H

D

G

 

Glass Door

1.5"

 

(Optional)

13.5"

 

 

N O

 

W

L

V

M

 

 

Model 36

Model 42

Model 36

Model 42

Model 36

Model 42

A

29"

36"

I

40 1/4"

44 1/4"

Q

13 7/8"

14"

B

5/8"

5/8"

J

21"

24"

R

10 1/2"

12 1/2"

C

41"

48"

K

8"

9"

S

2 1/2"

2 1/2"

D

12"

14"

L

34 3/4"

42"

T

8 1/8"

8 1/8"

E

21 1/4"

23"

M

42"

49"

U

11"

12 3/4"

F

22 1/4" (24" w/o Brick)

29 1/4" (31" w/o Brick)

N

36"

40"

V

7"

7"

G

32 5/8" (34" w/o Brick)

39 1/2" (41 1/4" w/o Brick)

O

37"

41"

W

2 1/4"

2 1/4"

H

15 3/4" (16 3/4" w/o Brick)

17 3/4" (18 3/4" w/o Brick)

P

8 5/8"

10 1/2"

X

5"

4 1/2"

Figure 2 - Appliance Dimensions

6

www.fmiproducts.com

108796-01U