Venting Installation

Continued

Stainless

RLT-12D

Inner Flue

Chase

Pipe

 

Top

Screen

 

1" Non-

 

 

com-

 

Secure

bustible

1"

Termination

Spacer

Space

to Outer

Apply

Pipe with 3

Waterproof

Screws

Caulking

 

Storm

 

Collar

 

Flashing

Overlap

 

Shingles (Top

Underlap

and Sides of

Shingles

Flashing Base)

 

Figure 26 - Terminations

Chase installations

Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. Terminations must be separated a minimum of 30" center to center and stacked at a minimum vertical height difference of 18" (see Figure 27).

Note: If a decorative shroud is to be installed, contact the manufacturer for specifications.

finishing fireplace

Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncom- bustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive.

Installing fireplace facing

Any noncombustible material may be used for facing (glass, tile, brick, etc.) as long as proper clearances are adhered to and fireplace openings are not obstructed in any way (see Minimum Clearance to Combustibles, page 4 and Figure 28).

Use only heat resistant, noncombustible mortar or adhesive when securing facing material to front of fireplace. When placing facing at upper edge of effective opening of fireplace, provide “L” shaped piece of metal extending full width of opening (see Figure 28).

Secure with sheet metal screws at a distance high enough from edge so it doesn't interfere with operation of doors. This assures that facing material will not block openings.

Noncombustible

Facing Material

 

“L” Shaped

Do Not

 

Metal

 

Support

Block

 

 

Opening

 

Noncombustible

18"

Facing Material

Min.

 

 

Typ.

Figure 28 - Fireplace Facing (Your

 

24" Min.

Fireplace May Vary from Illustration)

24" Min.

Figure 27 - Multiple Chase Installation

115607-01D

www.fmiproducts.com