Optional Gas Line Installation
Continued
CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANYAPPLIANCE IFALEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BYAQUALIFIED SERVICE PERSON.
Note: A FMI PRODUCTS, LLC hood must be installed when using an unvented gas log set (see Accessories on page 16).
Outside of |
| Side | |
| Firebrick | ||
Fireplace | Incoming | ||
Finished | |||
| |||
Gas | 1/2" Black | Side | |
Line | Iron Pipe |
| |
Conduit |
|
|
Seal
Opening
Repack with
Insulation Refractory
Cement
Provide Enough Threaded
End for Fitting Connection
Figure 20 - Gas Line Installation
WARNING: Do not operate an unvented gas log set in this fireplace with the chimney removed.
If you install a decorative gas appliance (vented gas log), the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60, Z21.84 or RG
WARNING:Toavoidtheriskof damagingthefireplacematerials andincreasingtheriskofspreading a fire, do not use the fireplace to cook or warm food.
WARNING: If the fireplace hasbeenusedforwoodburning, the firebox and chimney must be cleaned of soot, creosote and ashes be a qualified chimney cleaner. Creosote will ignite if heavily heated.
WARNING: When using a decorative vented gas log, the damper must be removed or permanently locked in the fully open positionandtheglassdoorsmust be in the fully open position.
Operation and Maintenance Guidelines
Glass Doors
Glass doors are optional with the fireplace. When the fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 21).
A fireplace equipped with glass doors operates mush differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Excessive heat within the fireplace can result if too large a fire is built or if the combustion air gate is not completely open.
Doors Fully Closed
Fireplace Front
Doors
Fully Opened
Fireplace Front
Figure 21 - Glass Doors
12 | www.fmiproducts.com |