2 - 76
Available Memory
Set the memory to the extent of the memory range of each PLC model.
Use TYPE number to assign indirect memory for macro programs.
Switch Setting
1785-KE
SW1 (protocol)
SW2 (port)
Specify the port for 1785-KE. (This port should not be duplicated in the network.)
1
No
3
4
ON
OFF
ON
Setting Contents
Duplicate message unacceptable
5OFF Handshaking signal ignored
6ON Diagnosis execution
BCC, Even, no
2OFF
26 Allen-Bradley PLC • 1
Memory TYPE Remarks
N(integer) 0
B(bit) 1
T.ACC (timer/current value) 2
T.PRE (timer/set value) 3
C.ACC (counter/current value) 4
C.PRE (counter/set value) 5
I(input) 6
O(output) 7
S(status) 8
T(timer/control) 9
C(counter/control) 10
R(control/control) 11
R.LEN (control/data length) 12
R.POS (control/data position) 13
D(BCD) 14
A (ASCáU) 15
1
No
3
4
ON
Setting Contents
5
6
2ON
7
8
1st digit (octal)
2nd digit (octal)
3rd digit (octal)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF