1 - 39
16 Connection
Up to 4 units can be connected to one PLC.
Use the terminal converter (UG00P-TC) , the optional equipment made by Fuji Electric Co., Ltd.
For details, please see the “User’s Manual <Multi-link 2 > (FEH364)”.
* Wire the shielded FG only at the one of both sides so that they are not connected.
Set the dip switch (SW1) of UG00P-TC as 2-wire connection when the UG00P-TC terminal converter is used.
Short-circuit between +RD and +SD , -RD and -SD when the UG00P-TC terminal converter is not used.
(b) (c) (d) (e)
Signal
FG
+SD
-
SD
+RD
-
RD
SG
SG
SG
Terminal block
prepared by user
terminal resistance
(OFF)terminal resistance
(OFF)
Signal
+
-
Signal
FG
+SD
-
SD
+RD
-
RD
SG
terminal resistance
(ON)
terminal resistance
(ON)
Signal
FG
+SD
-
SD
+RD
-
RD
SG
POD Master
MJ1/2
+
-
POD Slave
CN1
+
UG00P-TC POD Slave
CN1
+
UG00P-TC POD Slave
CN1
+
UG00P-TC
<Type> <Calendar>
A.B : Micro Logix 1000 Not provided
GE Fanuc : 90 series Not provided
GE Fanuc : 90 series(SNP-X) Not provided
TOSHIBA : T series Provided
SIEMENS : S5 Not provided
SIEMENS : S7 Not provided
SIEMENS : S5 UG400 Not provided
SIEMENS : TI500/505 Provided
SIEMENS : TI500/505(UG400) Provided
SIEMENS : S5 PG port Not provided
SIEMENS : S7-300MPI(HMI ADP) Not provided
SIEMENS : S7-300MPI(PC ADP) Not provided
SAMSUNG : SPC series Not provided
SAMSUNG : N_plus Provided
SAMSUNG : SECNET Depends on the model
KEYENCE : KZ series Not provided
KEYENCE : KZ-A500 CPU Port Provided
KEYENCE : KZ/KV series CPU Not provided
KEYENCE : KZ24/300 series CPU Not provided
KEYENCE : KV10/24 series CPU Not provided
KEYENCE : KV700 series CPU Provided
LG : MASTER-K10/60/200 Not provided
LG : MASTER-K500/1000 Not provided
LG : LGMKX00S Not provided
LG : MASTER-KxxxS CNET Not provided
LG : GLOFA CNET Not provided
FANUC : Power Mate Not provided
FATEK AUTOMATION: FACON FB series Provided
IDEC : MICRO3 Provided
MODICON : Modbus RTU Depends on the model
YAMATAKE : MX series Provided
TAIAN : TP02 Provided
SAIA : PCD Provided
MOELLER : PS4 Not provided
Telemecanique : TSX Micro Not provided
Automationdirect : Direct LOGIC Depends on the model
Automationdirect
: Direct LOGIC(K-Sequence) Depends on the model
TOYO : uGPC sx series Provided
TOYO : uGPC sx CPU Provided
<Type> <Calendar>
FUJI : MICREX-F series Depends on the model
FUJI : MICREX-SX series Provided
FUJI : MICREX-SX CPU Provided
FUJI : FLEX-PC series Depends on the model
FUJI : FLEX-PC CPU Depends on the model
FUJI : FLEX-PC COM(T) Provided
FUJI : FLEX-PC(T) Depends on the model
FUJI : FLEX-PC CPU(T) Depends on the model
MITSUBISHI : AnA/N/U series Provided
MITSUBISHI : QnA series Provided
MITSUBISHI : ACPU Port Provided
MITSUBISHI : FX series Depends on the model
MITSUBISHI : QnACPU Port Provided
MITSUBISHI : QnHCPU Port (A) Provided
MITSUBISHI : QnHCPU Port (Q) Provided
MITSUBISHI : FX series Link(A prt) Provided
MITSUBISHI : FX2N series Depends on the model
MITSUBISHI : FX1S series Provided
OMRON : SYSMAC C Depends on the model
OMRON : SYSMAC CV Provided
OMRON : SYSMAC CS1 Provided
SHARP : JW series Provided
SHARP : JW100/70H COM Port Provided
SHARP : JW20 COM Port Provided
HITACHI : HIDIC-H Provided
HITACHI : HIDIC-S10/2 alpha Not provided
HITACHI : HIDIC-S10/ABS Not provided
MATSUSHITA : MEWNET Depends on the model
YOKOGAWA : FA500 Provided
YOKOGAWA : FA-M3 Provided
YOKOGAWA : FA-M3R Provided
YASKAWA : Memobus Depends on the model
YASKAWA : CP9200SH/MP900 Not provided
TOYOPUC Provided
KOYO : SU/SG Depends on the model
KOYO : SR-T Provided
KOYO : SR-T(K prt) Not provided
KOYO : SU/SG(K-Sequence) Depends on the model
A.B : PLC-5 Not provided
A.B : SLC500 Provided