227
CHAPTER 2 DEPENDENCE FUNCTIONS
■Displaying All Machine CyclesDetailed information at all sampled machine cycles can be displayed.
In this mode, no source is displayed irrespective of the setup defined by the SET SOURCE command.
[Example]
>SHOW TRACE/CYCLE -587
frame no. address data a-status d-status Qst dfg
-00587 : FF0106 0106 --- ------- FLH
-00586 : FF0106 0008 ECF EXECUTE --- @
-00585 : FF0106 0106 --- EXECUTE ---
-00584 : 1010E8 10E8 --- ------- ---
-00583 : 1010E8 0102 EWA EXECUTE --- @
-00582 : 1010E8 0102 --- EXECUTE ---
-00581 : 000186 0186 --- ------- 2by
-00580 : 000186 10F2 IRA EXECUTE --- @
-00579 : 1010E6 10E6 --- ------- ---
-00578 : 1010E6 10F2 EWA EXECUTE --- @
-00577 : 1010E6 10F2 --- EXECUTE ---
-00576 : 000186 0186 --- ------- ---
Data Access
internal read access
:
Read access to
internal memory
internal write access
:
Write access to
internal memory
external read access
:
Read access to
external memory
external write access
:
Write access to
external memory
>SHOW TRACE
/INSTRUCTION
-194
step no. address mnemonic
\sub4:
-00194 : FF0106 LINK #00
-00193 : 000186 internal read access. 10F2
-00192 : 1010E6 external write access. 10F2
-00191 : 000186 internal write access. 10E6
-00190 : FF0108 ADDSP
#F8
-00189 : FF010A MOVL
A,001A
-00188 : 10001A external read access. 0000
-00187 : 10001C external read access. 4000
-00186 : FF010E MOVL
@SP+04,A
-00185 : 1010E2 external write access. 0000
-00184 : FF0111 MOVL
A,0016
5
-00183 : ** RESET **
>
Step Number
Address
Disassemble
Description
Data
Device Status
Decimal number,
Hexadecimal Indecates instruction
executed
Hexadecimal
** STANDBY **
:
Hardware standby
** RESET **
:
Reset
** THOLD **
:
Tool hold
** UHOLD **
:
User hold
** WAIT **
:
Ready pin input
** SLEEP **
:
Sleep
** STOP **
:
Stop
number
signed
number