Appendix 3 REPLACING CONSUMABLES

During its operation, the inside ￿￿￿￿￿￿￿ glass of the ADF becomes very

hot .

Before replacing the consumables, turn its power off and unplug the AC adapter from the outlet. Wait at least

15minutes.

Consumables and Replacement Cycles

Below are specifications of consumable items and their recommended replacement cycles.

 

Parts

Standard
DescriptionReplacement
Number

 

Cycle

 

 

 

 

 

 

 

 

Pad ASSY

PA03289-

After 50,000 scans

 

0111

or one year

 

 

 

Pick roller

PA03289-

After 100,000

 

0001

sheets or one year

 

 

 

To purchase consumables, contact the store where you purchased the scanner or an authorized FUJITSU scanner service provider.

The replacement cycles above are rough guidelines when using A4 or Letter woodfree or wood containing

paper 64 g/m2 (17 lb). This cycle varies according to the type of paper and how frequently the scanner is used and cleaned.

Use only the specified consumables.

ATTENTION

Do not use other consumables.

The illustration below demonstrates the locations of the replacement parts. Refer to "Chapter 4 Replacing Con- sumables" fi-4120C2 Operator’s Guide on the Setup CD-ROM.

Replacing the Pad ASSY

Replacing the Pick Roller

Pick Roller

Pick Roller's Shaft

fi-4120C2 Image Scanner Getting Started

 

AP-5