3. SETTING AND ADJUSTMENT

3.1DIP Switch Setting

The processor unit is shipped for model FAR-2137S. If your model is FAR-2837S/2137S-BB, change the DIP switch setting as follows.

1.Remove the top cover of the processor unit.

2.Open the SPU assembly block and remove the shield cover.

Shield cover

SPU assembly block

SPU board 03P9337

DIP switch S1

3. Set the DIP switch S1 as follows.

OFF

1

2

3

4

S1

ON

 

 

 

 

S1

Monitor SXGA for

Monitor UXGA for

FAR-2137S-BB

 

 

 

FAR-2137S

FAR-2837S (For

 

 

 

(Default)

MU-231CR

 

 

 

 

S. No. 0269 and later)

 

 

1

OFF

ON

OFF

 

2

OFF

OFF

ON

 

3

 

Not used.

 

 

4

 

 

 

 

 

 

Note: Set #1 and #2 of S1 to OFF for MU-231CR S. No. 0268 and earlier.

3-1

Page 41
Image 41