Furuno FR-1710 manual Peformance Monitor, Alarms con’t

Models: FR-1710

1 78
Download 78 pages 34.45 Kb
Page 50
Image 50

Table 1-6 Alarms (con’t)

Fault

Audible alarm

Visual alarm

To quit alarm status

 

 

 

 

Video signal

Continuous beep

VIDEO SIGNAL MISSING

To silence the beep, press the

failure

 

appears.

[AUDIO OFF] key. Buzzer

 

 

 

sounds again when the range

 

 

 

is changed.

 

 

 

 

Heading line

Continuous beep

HL SIGNAL MISSING

To silence the beep, press the

failure

 

appears.

[AUDIO OFF] key. Buzzer

 

 

 

sounds again when the range

 

 

 

is changed.

 

 

 

 

EPA plotting

None

UPDATE PLOT informs that

Reacquire the flashing target

 

 

a target which was once

within 5 min, or disregard the

 

 

plotted has not been re-

target if it is not necessary to

 

 

plotted within 10 minutes.

track the target.

 

 

 

 

Target on collision

Beeps

COLLISION appears when

Take evasive action or

course

 

EPA- or ATA-tracked target

terminate tracking of target.

 

 

is on collision course.

Then, visual indication goes

 

 

 

off.

 

 

 

 

1.49 Peformance Monitor

The performance monitor (PM-30 for FR-1710/1725, PM-50 for 1760DS) provides an effec- tive means of general performance check of a radar installation. It works like a transponder. Installed in the proximity of the radar antenna, it is triggered by part of the transmitted micro- wave energy and sends back a coded signal to the antenna for display on the radar screen. Overall performance can be checked from the range, size and number of arcs displayed on the radar screen. For further details see the operator’s manual of the performance monitor.

To turn on the performance monitor:

1.Press the [MENU] key.

2.Press the [0] key twice to display the OTHER menu.

3.Press the [5] key twice to open the DISPLAY menu.

 

 

DISPLAY

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

2.

NAV DATA

 

OFF

 

ON

 

 

 

 

 

3. DISPLAY

 

MAIN

SUB

 

 

 

 

 

4. SART

 

OFF

 

ON

5. P M

 

 

 

ON

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1-57 DISPLAY menu

4.Press the [5] key to select ON or OFF from the P M field as appropriate.

5.Press the [ENTER/SELECT] key followed by the [MENU] key.

When the performance monitor is turned on the radar is automatically set up as follows: IR, Off; ECHO AVG, Off; ES, Off; A/C AUTO, Off, N REJ, Off, RANGE, 24 nm.

1-36

Page 50