Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)

46
www GarrettCom com
..

Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)

Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]

where the “Cable Loss” for 62.5/125 and 50/125µm (M.m) is 2.8 dB/km,

and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,

and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km

and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25) and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (LXSC40) and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)

The following data has been collected from component manufacturer’s (Agilent’s and

Lucent’) web sites and catalogs to provide guidance to network designers and installers.

Fiber
Port
Module
Speed,
Std.
Mode
Std.
km
fdx
(hdx)
Wave
-
length
nm
Cable
Size
µm
X’mitr
Output
P
T ,
dB
R’cvr
Sens.
P
R ,
dB
Worst
OPB,
dB
Worst*
distance
Km, fdx
typical
OPB,
dB
typical*
distance
Km, fdx

6KP4V-

F10ST
10Mb
FL
Multi-
Mode 2
(2) 850 62.5/125
100/140
50/125
-15.0
-9.5
-19.5
-31
-31
-31
14
19.5
19.5
5
5.9
3.4
17
23.5
13.5
6
7
4.8
6KPV-
MST, MSC
100Mb
FX Multi-
mode 2
(0.4) 1300 62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
14
12
5
4
6KPV-SSC 100Mb
FX Single-
mode 18+
(0.4) 1300 9/125 -15 -31 14 28 17.5 35
6KPV-
SSCL
100Mb
FX Single-
mode 40
(0.4) 1300 9/125 -5 -34 29 58 32.5 65
6KPV-
MTRJ
100Mb
FX Multi-
mode 2
(0.4) 1300 62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
15.8
12.2
5.5
4.0
6KPV-
MLC
100Mb
FX Multi-
mode
2
(0.4) 1300 62.5/125 -19 -31 12 4 16 5.7
6KPV-SLC 100Mb
FX
Single-
Mode
15+
(0.4) 1310 9/125 -15 -28 11 22 - -
GBIC-
SXSC
1000Mb Multi-
mode
0.55
1300 62.5/125
50/125 -9.5 -17 5.5 2 12.5 4
GBIC-
LXSC10
1000Mb Single-
mode
10 1300 9/125 -9.5 -20 8.5 17 10.5 21
GBIC-
LXSC25
1000Mb Single-
mode
25 1550 9/125 -4.0 -21 15 37.5 17.5 43
GBIC-
ZXSC40
1000Mb Single-
mode
40 1550 9/125 -4.0 -21 15 60 17.5
70
GBIC-
ZXSC70
1000Mb Single-
mode
70 1550 9/125 -3.0 -23 18 90 20.5
102